Apnea Ventilation Settings Evita XL - Clinical Document   
This document provides a review of the process of setting the default apnea ventilation settings on the Evita XL. This document can also serve as a guide for the Evita 2 Dura and Evita 4 ventilators.

Comparable modes of ventilation, and enhancements can be achieved when going from the Babylog 8000 to the Evita XL. This document will highlight these comparisons.

Cleaning the Evita XL - Clinical Document   
Proper cleaning, disinfection and sterilization of reusable equipment are important components of the effort to reduce infections associated with medical equipment, especially with respiratory equipment. This document will cover basic cleaning principles for the Evita Series ventilators.

End Tidal CO2 Set up - Clinical Document   
This document provides detailed information regarding the set-up, calibration and troubleshooting of EtCO2 monitoring on the Evita XL and Evita Infinity V500 ventilators.

Evita Infinity V500 Modes - Device Tutorial   

This presentation will discuss the Evita Infinity V500 mode nomenclature, compare the modes on the Evita Infinity V500 to the Evita XL, and explain new modes of ventilation.


Use this chart to compare the various modes on the Evita Infinity V500 to the modes on the Evita XL.


Evita Series Competency Assessment Test - Competency Tests   
A 35 question comprehensive assessment for the Evita Series (Evita 2, Evita 4, Evita XL).

Evita Series: Battery Information - Device Tutorial   

This presentation covers information relating to both the internal and external back-up batteries for Draeger Evita Series Ventilators:  Evita 2, Evita 4, and Evita XL).


Evita XL Cleaning Competency Tutorial - Competency Tests   
This competency tutorial covers the proper cleaning, disinfection, and sterilization of the Evita XL and its accessories.

A 35 question comprehensive assessment test for the Evita XL (Adult and Pediatric patient range).

A 10 question comprehensive assessment test for the Evita XL (Neonatal patient range).

A 10 question comprehensive assessment test for the Evita XL, intended for nurses.

This presentation consists of a general overview of the Evita XL’s capabilities, its screen features, and its physical characteristics.

This module covers the functional setup and testing necessary to ensure proper function, and includes a full Readiness for Operation Check, which is also known as a System Check.

This module is the first in a set of two and covers physical preparation of the machine itself, including assembly and peripherals. Safety information on the use of HME’s & bacterial filters is also included.

This document reviews the adjustment of the Pulse Threshold and Base Flow on the Evita XL ventilator.

Evita XL: Displaying MV leak - Device Tutorial   

This presentation defines MVLeak and presents the steps required to view it on an Evita XL.


Evita XL: PEEPi - Device Tutorial   

This presentation will cover the intrinsic PEEP Procedure on the Evita XL.


This presentation covers performing an airtight check on the Evita XL ventilator.


Evita XL: Software 6.0 - Clinical Document   
Maximize your ventilator's potential with this comprehensive reference on the features and enhancements available with the optional software 6.0 upgrade for the Evita XL.

Evita XL: Software 7.0 - Clinical Document   
This document is an overview of Software 7.0 on the Evita XL, covering new features and enhancements.

External Nebulization - Clinical Document   
This document covers the set-up procedure for external nebulization on the Evita 2 dura, Evita 4 and Evita XL ventilators.

Neonatal Internal Nebulization - Clinical Document   
This document will review the function and use of internal nebulization in the neonatal and pediatric patient ranges on the Evita Series ventilators. Document has been updated to include device specific information for the Evita Infinity V500, the Evita XL, the Evita 2 Dura, and the Evita 4.

Occlusion Pressure - Clinical Document   
This document will define and discuss measurement of PO.1, or occlusion pressure on the Evita XL, Evita 2 Dura, and Evita 4 ventilators.

RCP Evita XL Skills checklist - Skills Checklists   
A tool to assess level of competency with the Evita XL Ventilator.

RCP Evita XL manual - Competencies   
A comprehensive competency manual for the Evita XL.

RCP Evita XL Study Guide - Competencies   


RN Evita XL manual - Competencies   
A comprehensive competency manual for the Evita XL.

RN Evita XL Skills checklist - Skills Checklists   
A tool to assess level of competency with the Evita XL Ventilator.

Smart Care Guidelines on Evita XL - Clinical Document   
An overview of SmartCare as a knowledge based, decision support weaning system. Guidelines for set-up and use of SmartCare on the Evita XL will be discussed in this document.

Volume Not Constant!! - Clinical Document   
The ‘Volume Not Constant!!’ alarm is a phenomenon which occurs only during the use of AutoFlow on the Evita XL, Evita 4, and Evita 2 Dura. This document discusses this alarm and appropriate troubleshooting measures.